Accurate measurement of kWh, kvarh, & kVAh
Maximum demand registration of kW, kvar & kVA
Instrumentation of voltage, current, power, frequency & power factor
Time of Use (TOU) control with fexible programming for up-to 8 tarifs
2 load profles with recording of up-to 180 days at 30’ interval
4 event logs with configurable power quality or tampering events
High quality 11-digit LCD display with large characters & backlight
– Internal real-time clock (RTC) with super capacitor and backup battery
– Supports DLMS, IEC 62056-21, or MODBUS communication protocols
– Encapsulation type meter casing design for reliability and security
– Replaceable backup battery for meter reading without power

Product Description

Technical Specifications
P2000-D

ELECTRICAL MEASUREMENT & INSTRUMENTATION
Connection Type Direct connected (Whole current) Energy Total & per phase import/export kWh,
kvarh, kVAh; Absolute or net
metering
Measurement Modes 3-phase 4-wire 3-element Maximum Demand Total & per phase import/export kW,
kvar, kVA
Accuracy Class Class 1.0 Automatic Billing Data
Recording / MD Reset
Date & Time Programmable
Rated Voltage 240/415V Instantaneous Values Current, Voltage, Power, Average
Demand, Power factor, Phase
Angles and Frequency
Rated Current 10 (100) A
Starting Current < 0.1% I
Rated Frequency 50 Hz
Power Consumption
Voltage Circuit
Current Circuit
< 1W, < 2.5VA per Phase
< 0.1VA
MECHANICAL LOAD PROFILE
Dimensions 285 mm x 200 mm x 94mm Load Profile 2 configurable load profiles
Weight 2 kg (approximately) Channels 16 configurable channels
Insulation Protective Class II Available Data All energy, demand, &
instrumentation data (see above for
details)
Ingress Protection IP54 Integration Period 15 to 60 minutes configurable
Case / Terminal Cover High Quality Polycarbonate Memory Space Up-to 180 days with 30’ interval
Terminal Block Flame-Retardant Polycarbonate Data Retention 25 Years
ENVIRONMENT EVENT LOG
Working Temp. -25°C to +75°C Event Log 5 configurable event logs
Storage Temp. -40°C to +85°C Trigger Events Power break, phase failure, phase
voltage loss, voltage over, voltage
under, current loss, current over,
current imbalance, reverse current
flow, reverse power, reverse energy,
phase reverse, overload, terminal
cover open, meter top cover open
Humidity 0 – 95% non condensing Data Recording at Event 8 configurable channels of energy,
demand, & instrumentation data
recording
Insulation 0 – 95% non condensing Program Record Last 100 program records
Fast Transient Burst 4kV
Static Discharge 8kV Contact / 15kV Air Discharge
Impulse Voltage 12kV, 1.2/50 μs pulse
AC Voltage 4kV, 50Hz
REAL-TIME CLOCK TIME OF USE (TOU) CONTROL
Accuracy < 0.5 seconds / 24 hours Number of Tariffs 4 tariffs, or 8 tariffs (optional)
Backup Battery Lithium Battery (20 years life) Daily Profiles 12 daily profiles, 14 tariff slots
Backup Time ≥ 15 years without power Week Tables/Seasons 12 week tables, 12 seasons
Clock Synchronization Local or remote via AMR Holidays 120 special days (up-to 250)
DISPLAY PREPAYMENT & LOAD CONTROL
LCD Display  2 line, 8-digit LCD display Prepayment Feature STS certified via token or smart card
Display Mode Automatic, Push Button, Test User -Friendly
Prepayment Modes
Friendly hours/days, emergency
credit and vital necessity power
Display Item 200 configurable display items Load Control Scheduled / on-demand or event
triggered load control
Internal Contactor 100A internal contactor
INPUT & OUTPUT
Electric Pulse I/O 4 Programmable Ports
Test Pulse Output 400 – 8000 imp/kWh, kvarh
LED Pulse Output 400 – 8000 imp/kWh
Pulse Constant Programmable
Auxiliary Power 110V – 240V (optional)