| Technical Data – Atmos® | |
|---|---|
| Maximum Operating Pressure | 0.5 |
| Max. Pressure Loss | ≤ 2 |
| Operating Temperature | -25 ~ +55 °C |
| IP Degree | IP65 |
| Working Voltage | 4.8 ~ 6.5 V |
| Average Current | ≤ 25 |
| Battery Life | ≥ 10 years (1 upload/day) |
| Battery Type | Lithium battery |
| Data Storage | 10 |
| Communication Mode | Modbus |
| Meter Reading Success Rate | 95% |
| Network Scale (Single Concentrator) | > 2000 |
| Sizes | IG4S-W: 0.04–6 m³/h IG6S-W: 0.06–10 m³/h IG10S-W: 0.10–16 m³/h IG16S-W: 0.16–25 m³/h IG25S-W: 0.25–40 m³/h |
| Housing Material | Galvanized steel sheet |
| Gas Media | • Natural gas • Town gas • Biogas • LPG • Methane gas |
| Performance Characteristics | |
| Battery | Pre-installed long-life battery |
| Reporting | Configurable reporting interval |
| Wireless Transmission | Long-range, > 5 km (open space) |
| Maintenance | Maintenance-free – install & forget |
| Protocol | Modbus international standard compliant |
| Data Upload | Automatic, with precise power control |
| Remote Control | Remote settable block pricing and valve control |
| Billing Records | Daily and monthly data available |
| Certification | MID approved by NMi |
| Error Adjustment | Integrated system to adjust error curve |
| Housing Protection | Powder-coated galvanized steel for corrosion resistance |
| Stability | High-quality diaphragms ensure long-term accuracy |
| Pulser Option | Retrofittable with pulser |
| Optional | Reverse flow preventer |
| ELECTRICAL – Measurement & Instrumentation | |
|---|---|
| Connection Type | Direct connected (Whole current) |
| Energy | Import/export kWh, kvarh; Absolute or net metering |
| Measurement Modes | 1-phase 2-wire or 2-phase 3-wire |
| Maximum Demand | Import/export kW, kvar |
| Accuracy Class | Class 1.0 |
| Billing Data / MD Reset | Date & Time Programmable |
| Rated Voltage | 110V, 220V, 230V, or 240V |
| Instantaneous Values | Current, Voltage, Power, Demand, Power factor, Frequency |
| Rated Current | 5 (60) A, 10 (100) A |
| Starting Current | < 0.1% I |
| Rated Frequency | 50 Hz |
| Power Consumption | Voltage Circuit: < 1W, < 2.5VA per Phase Current Circuit: < 0.1VA |
| MECHANICAL – Load Profile | |
| Dimensions | 209 mm x 137 mm x 83mm |
| Weight | 1 kg (approx.) |
| Insulation | Protective Class II |
| Ingress Protection | IP54 |
| Case / Terminal Cover | High Quality Polycarbonate |
| Terminal Block | Flame-Retardant Polycarbonate |
| Load Profile | Configurable |
| Channels | 8 configurable channels |
| Available Data | All energy, demand & instrumentation data |
| ENVIRONMENT – Event Registration | |
| Working Temp. | -25°C to +70°C |
| Storage Temp. | -40°C to +85°C |
| Humidity | 0 – 95% non-condensing |
| Fast Transient Burst | 4kV |
| AC Voltage | 4kV, 50Hz |
| Static Discharge | 8kV Contact / 15kV Air |
| Impulse Voltage | 12kV, 1.2/50 μs pulse |
| Event Log | Configurable event log |
| Trigger Events | Voltage loss/over/under Current loss/over/reverse Low power factor, overload Terminal/top cover open Power on/off |
| Program Record | Last 100 program records |
| REAL-TIME CLOCK – TOU | |
| Accuracy | < 0.5 seconds / 24 hours |
| Backup Battery | Lithium (20 years life) |
| Backup Time | ≥ 15 years |
| Clock Sync | Local or remote via AMR |
| Number of Tariffs | 4 tariffs |
| Daily Profiles | 4 daily profiles, 10 tariff slots |
| Week Tables/Seasons | 4 week tables, 4 seasons |
| Holidays | 100–200 special days |
| DISPLAY – Input & Output | |
| LCD Display | 2 line, 8-digit |
| Display Mode | Auto / Push Button |
| Display Items | 100 configurable |
| Display at Power Off | Active or net energy |
| Test Pulse Output | 400–4000 imp/kWh |
| LED Pulse Output | 400–4000 imp/kWh |
| COMMUNICATION – Prepayment & Load Control | |
| Local Communication | Optical/IR, RS232, RS485, PLC, RF (433/866MHz) |
| Remote Communication | GPRS/GSM, Wi-Fi, Ethernet |
| Protocol | DLMS/COSEM, IEC62056-21, MODBUS |
| Prepayment Feature | STS certified via token or smart card |
| Prepayment Modes | Friendly hours, emergency credit, vital necessity power |
| Load Control | Scheduled / on-demand / event triggered |
| Internal Contactor | 100A internal |

The Smart Diaphragm Gas Meter (Modbus version) applications are growing rapidly with the Internet of Things deployment, it realized collecting data from the distances of many miles or kilometers, being perfect choice for suburban areas.
The Atmos® series of commercial gas meter is extremely suitable for the conditions of hotels, restaurants, factories and other commercial settings. The meter is characterized by precise measurements, a constant measuring stability, a long life and high reliability. Thanks to the use of high-grade materials, the diaphragm gas meter is resistant to corrosion. The gas meter is suitable for various gas media.
The Atmos® XL industrial & commercial Diaphragm gas meter meets the requirements of the EN1359:1998/ A1:2006 and OIML R137-1 (2012) standards.
| Technical Data – Atmos® | |
|---|---|
| Maximum Operating Pressure | 0.5 |
| Max. Pressure Loss | ≤ 2 |
| Operating Temperature | -25 ~ +55 °C |
| IP Degree | IP65 |
| Working Voltage | 4.8 ~ 6.5 V |
| Average Current | ≤ 25 |
| Battery Life | ≥ 10 years (1 upload/day) |
| Battery Type | Lithium battery |
| Data Storage | 10 |
| Communication Mode | Modbus |
| Meter Reading Success Rate | 95% |
| Network Scale (Single Concentrator) | > 2000 |
| Sizes | IG4S-W: 0.04–6 m³/h IG6S-W: 0.06–10 m³/h IG10S-W: 0.10–16 m³/h IG16S-W: 0.16–25 m³/h IG25S-W: 0.25–40 m³/h |
| Housing Material | Galvanized steel sheet |
| Gas Media | • Natural gas • Town gas • Biogas • LPG • Methane gas |
| Performance Characteristics | |
| Battery | Pre-installed long-life battery |
| Reporting | Configurable reporting interval |
| Wireless Transmission | Long-range, > 5 km (open space) |
| Maintenance | Maintenance-free – install & forget |
| Protocol | Modbus international standard compliant |
| Data Upload | Automatic, with precise power control |
| Remote Control | Remote settable block pricing and valve control |
| Billing Records | Daily and monthly data available |
| Certification | MID approved by NMi |
| Error Adjustment | Integrated system to adjust error curve |
| Housing Protection | Powder-coated galvanized steel for corrosion resistance |
| Stability | High-quality diaphragms ensure long-term accuracy |
| Pulser Option | Retrofittable with pulser |
| Optional | Reverse flow preventer |


| ELECTRICAL | |
|---|---|
| Connection Type | Direct connected (Whole current) |
| Measurement Modes | 3-phase 4-wire 3-element |
| Accuracy Class | Class 1.0 |
| Rated Voltage | 240/415V |
| Rated Current | 10 (100) A |
| Starting Current | < 0.1% I |
| Rated Frequency | 50 Hz |
| Power Consumption | Voltage Circuit: < 1W, < 2.5VA/Phase Current Circuit: < 0.1VA |
| MEASUREMENT & INSTRUMENTATION | |
| Energy | Total & per phase import/export kWh, kvarh, kVAh; Absolute or net metering |
| Maximum Demand | Total & per phase import/export kW, kvar, kVA |
| Automatic Billing / MD Reset | Date & Time Programmable |
| Instantaneous Values | Current, Voltage, Power, Avg Demand, PF, Phase Angles, Frequency |
| MECHANICAL | |
| Dimensions | 285 mm x 200 mm x 94 mm |
| Weight | 2 kg (approx.) |
| Insulation | Protective Class II |
| Ingress Protection | IP54 |
| Case / Terminal Cover | High Quality Polycarbonate |
| Terminal Block | Flame-Retardant Polycarbonate |
| LOAD PROFILE | |
| Load Profile | 2 configurable load profiles |
| Channels | 16 configurable channels |
| Available Data | All energy, demand, instrumentation data |
| Integration Period | 15 to 60 minutes configurable |
| Memory Space | Up to 180 days (30-min interval) |
| Data Retention | 25 Years |
| ENVIRONMENT | |
| Working Temp. | -25°C to +75°C |
| Storage Temp. | -40°C to +85°C |
| Humidity | 0 – 95% non-condensing |
| Insulation | 0 – 95% non-condensing |
| Fast Transient Burst | 4kV |
| Static Discharge | 8kV Contact / 15kV Air |
| Impulse Voltage | 12kV, 1.2/50 μs |
| AC Voltage | 4kV, 50Hz |
| REAL-TIME CLOCK | |
| Accuracy | < 0.5 sec / 24 hours |
| Backup Battery | Lithium Battery (20 years) |
| Backup Time | ≥ 15 years without power |
| Clock Synchronization | Local or remote via AMR |
| TIME OF USE (TOU) | |
| Number of Tariffs | 4 tariffs (8 optional) |
| Daily Profiles | 12 daily profiles, 14 tariff slots |
| Week Tables / Seasons | 12 week tables, 12 seasons |
| Holidays | 120 special days (up to 250) |
| DISPLAY | |
| LCD Display | 2 line, 8-digit LCD |
| Display Mode | Automatic, Push Button, Test |
| Display Items | 200 configurable items |
| PREPAYMENT & LOAD CONTROL | |
| Prepayment Feature | STS certified via token or smart card |
| User-Friendly Modes | Friendly hours/days, emergency credit, vital necessity power |
| Load Control | Scheduled, on-demand, or event-triggered |
| Internal Contactor | 100A |
| INPUT & OUTPUT | |
| Electric Pulse I/O | 4 Programmable Ports |
| Test Pulse Output | 400 – 8000 imp/kWh, kvarh |
| LED Pulse Output | 400 – 8000 imp/kWh |
| Pulse Constant | Programmable |
| Auxiliary Power | 110V – 240V (optional) |
| EVENT LOG | |
| Event Log | 5 configurable logs |
| Trigger Events | Power break, phase failure, voltage/current issues, reverse current/power/energy, phase reverse, overload, terminal/meter cover open |
| Event Data Recording | 8 configurable channels of energy, demand & instrumentation |
| Program Record | Last 100 program records |


| ELECTRICAL – Measurement & Instrumentation | |
|---|---|
| Connection Type | Direct connected (Whole current) |
| Energy | Import/export kWh, kvarh; Absolute or net metering |
| Measurement Modes | 1-phase 2-wire or 2-phase 3-wire |
| Maximum Demand | Import/export kW, kvar |
| Accuracy Class | Class 1.0 |
| Automatic Billing Data Recording / MD Reset | Date & Time Programmable |
| Rated Voltage | 110V, 220V, 230V, or 240V |
| Instantaneous Values | Current, Voltage, Power, Average Demand, Power factor, & Frequency |
| Rated Current | 5 (60) A, 10 (100) A |
| Starting Current | < 0.1% I |
| Rated Frequency | 50 Hz |
| Power Consumption | Voltage Circuit: < 1W, < 2.5VA per Phase Current Circuit: < 0.1VA |
| MECHANICAL – Load Profile | |
| Dimensions | 209 mm x 137 mm x 83 mm |
| Weight | 1 kg (approx.) |
| Insulation | Protective Class II |
| Ingress Protection | IP54 |
| Case / Terminal Cover | High Quality Polycarbonate |
| Terminal Block | Flame-Retardant Polycarbonate |
| Load Profile | Option of configurable load profile |
| Channels | 8 configurable channels |
| Available Data | All energy, demand, & instrumentation data |
| ENVIRONMENT – Event Registration | |
| Working Temp. | -25°C to +70°C |
| Storage Temp. | -40°C to +85°C |
| Humidity | 0 – 95% non-condensing |
| Fast Transient Burst | 4 kV |
| AC Voltage | 4 kV, 50 Hz |
| Static Discharge | 8 kV Contact / 15 kV Air Discharge |
| Impulse Voltage | 12 kV, 1.2/50 μs pulse |
| Event Log | Configurable event log |
| Trigger Events | Voltage loss, over, under Current loss, over, reverse Low power factor, overload Terminal/top cover open Power on/off |
| Program Record | Last 100 program records |
| REAL-TIME CLOCK – Time of Use (TOU) | |
| Accuracy | < 0.5 seconds / 24 hours |
| Backup Battery | Lithium Battery (20 years life) |
| Backup Time | ≥ 15 years without power |
| Clock Synchronization | Local or remote via AMR |
| Number of Tariffs | 4 tariffs |
| Daily Profiles | 4 daily profiles, 10 tariff slots |
| Week Tables/Seasons | 4 week tables, 4 seasons |
| Holidays | 100 special days (up to 200) |
| DISPLAY – Input & Output | |
| LCD Display | 2 line, 8-digit LCD display |
| Display Mode | Automatic, Push Button |
| Display Item | 100 configurable display items |
| Display at Power Off | Active energy or net energy |
| Test Pulse Output | 400 – 4000 imp/kWh |
| LED Pulse Output | 400 – 4000 imp/kWh |
| COMMUNICATION – Prepayment & Load Control | |
| Local Communication | Optical/Infrared, RS232, RS485, PLC, RF (433/866MHz) |
| Remote Communication | GPRS/GSM, Wi-Fi, Ethernet |
| Communication Protocol | DLMS/COSEM, IEC62056-21, MODBUS |
| Prepayment Feature | STS certified via token or smart card |
| Prepayment Modes | Friendly hours/days, emergency credit, vital necessity power |
| Load Control | Scheduled / on-demand or event triggered load control |
| Internal Contactor | 100A internal contactor |


MPI digital kWh energy meters are manufactured using advanced energy metering chip,
digital sampling, and SMT technology. They are designed and manufactured according
to strict quality standards, ensuring the highest reliability in terms of energy
measurement accuracy. The meters conform to IEC 62053-21:2003 standards.
The meter measures active total energy and displays the consumption on a large
LCD screen with a 7.1 digit format.
| SPECIFICATION AND TECHNICAL DATA | |
|---|---|
| Voltage (Un) | 3 x 240V / 415V |
| Frequency | 50 Hz |
| Accuracy | Class 1.0 |
| Operating Voltage | 0.7Un ~ 1.2Un |
| Circuit Consumption | ≤ 0.6 VA |
| Operating Temperature | -10°C ~ +60°C |
| Humidity | ≤ 95 % |
| Display | LCD 7+1 Digits (9999999.9) |
| Approximate Weight | 1.6 kg |
| External Dimension | 250 mm x 171 mm x 60 mm (H x W x D) |
| Standard | IEC62053-21 |

EM-10 is a solid-state single phase LCD energy meter designed for high accuracy and reliability.
It supports RS-485 communication for automated remote meter reading and complies
with applicable standards of IEC 62052-11 and IEC 62053-21.
The meter features a large LCD display with 6+2 digits for easy read-out.
| SPECIFICATION AND TECHNICAL DATA | |
|---|---|
| Voltage (Un) | 240 VAC |
| Frequency | 50 Hz |
| Accuracy | Class 1.0 |
| Operating Voltage | 0.85Un ~ 1.2Un |
| Circuit Consumption | ≤ 10 VA |
| Operating Temperature | 0°C ~ +60°C |
| Humidity | ≤ 95 % |
| Display | LCD 6+2 Digits |
| Approximate Weight | 1.6 kg |
| External Dimension | 183 mm x 120 mm x 74 mm (H x W x D) |
| Standard | IEC 62053-21 |
| Communication | RS-485 |

Application
| FEATURES | |
|---|---|
| Application | Residential potable water consumption metering |
| Temperature Compensation | For cold water and hot water up to 50°C |
| Technology | No moving parts, wear-free ultrasonic technology |
| Sensor Body | Durable BRASS body for harsh environments |
| Performance | Excellent long-term stability, accuracy does not degrade over time |
| Leakage Detection | Customizable leakage detection |
| Temperature Monitoring | Inspection and low temperature alarm |
| Air Measurement | Does not measure entrained air in pipe |
| Flow Direction | Bi-directional flow |
| Pressure Drop | Low pressure drop |
| Installation | Free positioning for installation |
| Display | Large LCD display |
| Battery Life | More than 10 years |
| Protection | IP68 waterproof |
| Standards | MID / ISO 4064:2014 |
| Data Logger | 480 daily totals, 36 monthly totals, and 16 years totals |
| Communication | Wide communication possibilities |
| Alarm Functions | Low battery and system error alarms |




kWh: Class 1.0, 35mm DIN Rail installing
Multi tariff & Load management
Anti power stealing alarm
Support overdraw function
RS485, Modbus protocol
| BASIC FUNCTION | |
|---|---|
| Power System | Suitable for 120V, 220V, 230V, 240V AC power system |
| Prepaid Mode | Default prepaid mode, auto switch power by remaining energy |
| Other Modes | Selectable post-paid mode, lock mode |
| Display | LCD display for energy consumption and power measurement |
| History Records | Energy for latest 31 days & latest 12 months |
| Recharge Records | Information stored for the latest 50 times |
| Alarms & Abnormal Status | Trip, overload, and other abnormal status with records |

Advanced Gateway for the fast reading of data from meters with DLMS and MODBUS protocol.
Instantaneous conversion of reading to JomEMS.
The DLMS protocol (Device Language Message Specification) is used in the context of meters, particularly energy meters, for the reading of operating data.
The reference standard is IEC 62056. It is based on services that allow reading the objects, defined as OBIS, into which operating values of the meters are mapped according to standard profiles.
MODBUS Protocol is a messaging structure widely used to establish master-slave communication between intelligent devices.
A MODBUS message sent from a master to a slave contains the address of the slave, the command (e.g. "read register" or "write register"), the data, and a check sum (LRC or CRC).
Since MODBUS protocol is just a messaging structure, it is independent of the underlying physical layer. It is traditionally implemented using RS232, RS422, or RS485.
JomSoft provides an advanced gateway that allows communication with DLMS or MODBUS protocol, enabling the reading of data provided by meters equipped with these protocols.
The meters currently supported include:
Features:
| MODEL: JomEMS Advanced Gateway | |
|---|---|
| Processor | Broadcom BCM2711, Quad-Core Cortex-A72, 64-bit, 1.5 GHz |
| Ethernet | True Gigabit Ethernet |
| Storage | 16GB microSD |
| RAM | 4GB |
| USB Port | 2 x USB 3.0 + 2 x USB 2.0 |
| HDMI | 2 x micro HDMI, supports Dual Display |
| WiFi | 802.11 b/g/n/ac (2.4GHz + 5GHz, Shielded) |
| Bluetooth | 5.0 + BLE (Shielded) |
| RS-485 Baud Rates | 9.6k, 19.2k, 38.4k, 76.8k, 115.2k |
| Power | 5V via USB Type-C (up to 3A) |

JOMS500 is our new generation of wireless water meter for the projects which require for a reliable wireless communication to collect data automatically at a longer distance with lower power cost. LoRaWAN technology meets this requirement perfectly.
| Specification and Technical Data | |
|---|---|
| Diameter Nominal, mm | DN15-20 |
| Connection | Threaded joint |
| Class of Temp. | T30 / T50 |
| Class of Pressure Loss | △P < 63Kpa |
| Max. Permissible Working Pressure | 1.0 Mpa |
| Max Reading | 99999 m³ |
| Installation Direction | Horizontal |
| Detection Alert | Upstream |
| Data Storage | 18 months |
| Power Supply | Battery DC 3.6V, lithium battery (10+1 years lifetime) |
| Static Consumption | < 20µA |
| Communication Interface | IrDA, LoRa |
| Environment Protection | IP65 / IP68 |
| Environmental Class | E1, M1, A |
| Ambient Temp. | 5 ~ 55 ℃ |
| Storage Temp. | -20 ~ 60 ℃ |
| Standard (Meter Standard) | ISO4064, EN14154 |
| Communication | |
| Standard | LoRaWAN |
| Communication Manner | Automatic transmission |
| Distance | 4.0 km (LoRa etc.) |
| Band | 868 MHz, 433 MHz and other ISM band |
| Transmission Interval | 1 hour (Customizable) |

LoRaWAN Gateway is used to collect the data from water meters and transfer data to the server. It can connect thousands of water meters with long range of communication distance up to 2 or 3 km away in the urban area.
| Specification and Technical Data | |
|---|---|
| Power Supply | 12V, DC Power for Adaptor |
| Operating Temperature | -25℃ ~ 60℃ |
| Transport & Storage Temperature | -35℃ ~ 70℃ |
| Relative Humidity | 95% (Max) |
| Electromagnetic Class | E1 |
| Mechanical Class | M1 |
| Environment Class | A (Outdoor Installation) |
| Standard Compliance | LoRaWAN |
| Interface & Communication | LoRa, GSM/GPRS, GPS |
| LoRa Specifications | |
| Frequency | 470 / 868 MHz (Customizable) |
| TX Power | 19±1 dBm |
| Data Rate | 290 bps ~ 50 Kbps |
| Max Loading Meter Quantity | 2000 meters (1 transmission/h) |
| Max Communication Distance | 2 km (urban area); 5 km (rural area) |
| Functions | |
| Terminal Devices Entry | Network control |
| Control Time Gap | Avoids communication conflicts |
| Gateway Location Report | Enabled |
| Meter Clock Synchronization | Supported |
| Meter Alarm Report | Enabled |

| Product Shipping Information | |
|---|---|
| Weight | 0.5 kg |
| Shipping (East Malaysia) | RM15.00 |
| Engine Controller – Specification & Features | |
|---|---|
| Applications | Land-based and marine Tier4 applications |
| Functions | Control, monitoring, and protection for both mechanical and electronic diesel/gas engines in one unit |
| Engine Start/Stop | Automatic or manual |
| Panel Button | Programmable On/Off |
| ECU Support | Engines with Electronic Control Unit (ECU) – J1939 or Cummins Modbus |
| Analog Gauge Outputs | VDO, Datcon, and others – operator friendly |
| Engine Speed Control | Smooth speed regulation |
| Binary Inputs | 7 configurable |
| Binary Outputs | 7 configurable |
| Analog Inputs | 9 configurable (3 resistive, 4 voltage) + 2 fixed voltage inputs |
| Protections | Selectable: Alarm / Shutdown |
| Password Protection | 3 levels |
| Communication Interfaces | USB, RS485, RS232, Modem, Modbus |
| Alarm Notification | Automatic SMS on alarm |
| Remote Monitoring | On-line control & monitoring via embedded web server (IB-Lite) |
| Wireless Options | Optional GSM/GPRS modem, Internet via IL-NT GPRS, AirGate support |
| Languages | 2 (user changeable) |
| Real-Time Clock | Built-in with event history log |
| PLC Functions | PID loop, Comparators, Timers |
| Control Panel | Push buttons for simple control, lamp test |
| Protection Rating | Front panel sealed to IP65 |
| Certifications | EN, UL |
![]()